Fountain terminology glossary
1–1. Types of fountains and water effects
Translated term | English equivalent in the source | Functional definition |
|---|---|---|
Fountain / Water Feature | Fountain / Water Feature | A collection with the designed presence of water; The term Water Feature has a wider scope |
Urban Fountain | Urban Fountain | A fountain located in an urban space |
Decorative Fountain | Decorative Fountain | Mainly spectacular water feature, no admission required |
Static Fountain | Static Fountain | A fountain with a relatively constant pattern during operation |
Dynamic / Choreographed Fountain | Dynamic / Choreographed Fountain | A fountain with programmed changes in water movement |
Musical Fountain | Musical Fountain | Fountain synchronized with music |
Dry Deck Fountain | Dry Deck Fountain | A fountain with equipment embedded in the floor and collecting water below the surface |
Splash Pad | Splash Pad | A space designed for people to contact and play with water |
Interactive Fountain | Interactive Fountain | A water feature that responds to the presence or command of the audience |
Floating Fountain | Floating Fountain | A water fountain installed on a floating structure |
Water Curtain | Water Curtain | Continuous or dense arrangement of water drops |
Water Screen | Water Screen | The blue surface is suitable for displaying images with a projector |
Water Wall | Water Wall | Water flow on the surface or along the wall |
Artificial Waterfall | Artificial Waterfall | Designed water fall from height difference |
Vertical Jet | Vertical Jet | Water exit with a dominant vertical direction |
Laminar Jet | Laminar Jet | Consistent flow with low turbulence and clear appearance |
Jumping Jet | Jumping Jet | Segmented jet with on and off time control |
Fan Nozzle | Fan Nozzle | A nozzle that creates a water fan zone |
Foam / Aerating Nozzle | Foam / Aerating Nozzle | The nozzle creates a white and airy effect |
Bell Nozzle | Bell Nozzle | A bell-shaped water crust forming nozzle |
Fountain Ring | Fountain Ring | Circular arrangement of water outlets |
Misting System | Misting System | Very fine water droplet production system |
Jet Height | Jet Height | Measurable height of water effect under certain conditions |
Splash Envelope | Splash Envelope | The range that water droplets reach under defined conditions |
A dry floor fountain is not necessarily suitable for people to play with, simply because the nozzles are level with the floor; Interactive user should be foreseen in the design and operation.
1–2. Mechanical and hydraulic terms
Translated term | English equivalent in the source | Functional definition |
|---|---|---|
Flow Rate | Flow Rate | Flow volume of fluid per unit time |
Head | Head | Fluid energy per unit weight, expressed in meters of fluid column |
Total Dynamic Head — TDH | Total Dynamic Head — TDH | The required head of the system in a specified flow rate |
Static Head | Static Head | Contribution independent of the flow in the system head |
Head Loss | Head Loss | Energy reduction due to friction and track resistance |
Operating Pressure | Operating Pressure | Pressure when working at a given point |
Duty / Operating Point | Duty / Operating Point | The combination of flow rate and the actual working head of the pump |
Pump Curve | Pump Curve | The relationship between pump performance and flow rate |
System Curve | System Curve | The relationship between the required head of the system and the flow rate |
Efficiency | Efficiency | Ratio of useful power to input power |
Net Positive Suction Head — NPSH | Net Positive Suction Head — NPSH | Index of suction conditions to check the possibility of cavitation |
Cavitation | Cavitation | Formation and collapse of vapor bubbles in fluid |
Submersible Pump | Submersible Pump | Pump designed to work in submerged mode |
Dry-installed Pump | Dry-installed Pump | Pump installed outside the water |
Manifold / Header | Manifold / Header | Flow distribution or collection pipe or chamber |
Strainer | Strainer | Means for separating relatively large particles |
Check Valve | Check Valve | Reverse flow limiting valve |
Isolation Valve | Isolation Valve | Isolation valve for a part of the circuit |
Control / Regulating Valve | Control / Regulating Valve | Valve to change or regulate the flow |
Bypass | Bypass | Parallel path for specific performance |
Water Hammer | Water Hammer | A transient increase or decrease in pressure due to a rapid change in flow |
Dry Running | Dry Running | Pump operation without enough water |
Fountain Basin | Fountain Basin | The place of receiving and storing water |
Balance / Surge Tank | Balance / Surge Tank | The tank absorbs changes in volume and water level |
Make-up Water | Make-up Water | Added water to compensate for the deficit |
Overflow | Overflow | Excess water outlet |
Drain | Drain | Controlled water discharge path |
Air Gap | Air Gap | Physical separation of the incoming water outlet from the receiving level |
1–3. Electricity, lighting and control
Translated term | English equivalent in the source | Functional definition |
|---|---|---|
Electrical Control Panel | Electrical Control Panel | A set of distribution, protection and control equipment |
Variable Frequency Drive — VFD | Variable Frequency Drive — VFD | Motor speed control equipment by changing frequency and voltage |
Programmable Logic Controller — PLC | Programmable Logic Controller — PLC | Program logic execution controller |
Human–Machine Interface — HMI | Human–Machine Interface — HMI | The operator's communication page or tool with the system |
Show Control | Show Control | Synchronizing the timing of visual effects |
DMX512 | DMX512 | Display equipment command transmission protocol |
Remote Device Management — RDM | Remote Device Management — RDM | Two-way communication to identify, configure and report the status of compatible equipment |
Start Address | Start Address | The first channel dedicated to equipment |
Terminator | Terminator | Electrical terminator of the communication line |
Isolated Splitter | Isolated Splitter | Equipment for creating communication branches with proper isolation |
Underwater Luminaire | Underwater Luminaire | A light designed for specific underwater work conditions |
Power Supply Unit — PSU | Power Supply Unit — PSU | Equipping the supply of electric power suitable for the consumer |
Safety Isolating Transformer | Safety Isolating Transformer | Transformer with protective isolation for relevant application |
SELV | SELV | Very low voltage system with protective isolation requirements |
Protective Conductor — PE | Protective Conductor — PE | Conductor related to protection against electric shock |
Protective Equipotential Bonding | Protective Equipotential Bonding | Protective connection of specified components to limit potential difference |
Residual Current Device — RCD | Residual Current Device — RCD | Differential current detection and circuit breaker equipment |
Overload Protection | Overload Protection | Protection against sustained overload |
Short-circuit Protection | Short-circuit Protection | Protection against short circuit current |
Voltage Drop | Voltage Drop | Reduction of voltage in the feeding path |
Ingress Protection — IP | Ingress Protection — IP | Enclosure protection classification against access, solid objects and water |
Emergency Stop | Emergency Stop | Stop command to reduce specified risk |
Safety Interlock | Safety Interlock | A condition that allows the operation of the equipment to depend on the safe state |
Lockout / Tagout — LOTO | Lockout / Tagout — LOTO | Energy isolation control during repair work |
RDM in this application means two-way communication over a DMX compatible network; It does not necessarily mean internet connection. RDM standard in ANSI [439]
1–4. Refinement, exploitation and documents
Translated term | English equivalent in the source | Functional definition |
|---|---|---|
Filtration | Filtration | Separation of particles by passing through the filter medium |
Disinfection | Disinfection | The process of controlling pathogenic microorganisms |
Backwashing | Backwashing | Wash the filter with reverse flow according to the manufacturer's instructions |
Turbidity | Turbidity | Light scattering index caused by suspended particles |
Free Chlorine | Free Chlorine | Free and measurable portion of residual chlorine |
Combined Chlorine | Combined Chlorine | Chlorine in compounds such as chloramines |
pH | pH | Water acidity or alkalinity index |
ORP | ORP | Electrochemical index of oxidation-reduction state |
Biofilm | Biofilm | Microbial layer attached to the surface |
Turnover Time | Turnover Time | The ratio of the base volume of the system to the related flow rate |
Preventive Maintenance | Preventive Maintenance | Scheduled pre-breakdown service |
Commissioning | Commissioning | Checking and recording the performance of the system against the requirements |
As-built Drawing | As-built Drawing | The map corresponds to the implemented situation |
Operation & Maintenance Manual — O&M | Operation & Maintenance Manual — O&M | Instructions for use, service and troubleshooting |
Punch List | Punch List | List of remaining items for correction and completion |
Notes and references
Source 297: Standard RDM in ANSI; webstore.ansi.org. Full address in the bibliography.