Quick calculation tables

Read directly in English8 min read8 tables

Quick calculation tables

2–1. Convert flow rate

Qm3/h=0.06QL/min

Qm3/h=3.6QL/s

liters per minute

liters per second

cubic meters per hour

10

0.167

0.6

25

0.417

1.5

50

0.833

3

100

1.667

6

150

2.5

9

200

3.333

12

300

5

18

500

8.333

30

1000

16.667

60

For simultaneous nozzles:

Qtotal=∑ qi

The flow rate of the display circuit and the flow rate of the purification circuit must be defined separately.

2–2. Pressure and head conversion

For water with approximate density 1000 kg/m3:

H=pρ g

Hm≈10.20pbar

pressure, load

Pressure, kilopascals

Water equivalent head, m

0.1

10

1.02

0.25

25

2.55

0.5

50

5.10

0.75

75

7.65

1

100

10.20

1.5

150

15.30

2

200

20.39

3

300

30.59

The pump head should not be taken directly to the height of the fountain. The required head includes the nozzle exit conditions and path drops. Head definition in KSB technical reference [440]

2–3. Initial estimate of the inner diameter of the pipe

Q=vA

Dmm=18.81Qm3/hvm/s

The following table shows the flow rate in cubic meters per hour.

Actual inner diameter, mm

at a speed of 1 m/s

at a speed of 1.5 meters per second

at a speed of 2 meters per second

20

1.13

1.70

2.26

25

1.77

2.65

3.53

32

2.90

4.34

5.79

40

4.52

6.79

9.05

50

7.07

10.60

14.14

63

11.22

16.83

22.44

75

15.90

23.86

31.81

90

22.90

34.35

45.80

110

34.21

51.32

68.42

Method of use: For a flow rate of 12 cubic meters per hour and an assumed velocity of 1.5 meters per second, the calculated inner diameter is approximately 53.2 mm.

The inner diameter is not the same as the nominal diameter or outer diameter. The final selection should be controlled by product internal diameter, pressure drop, suction conditions, path length and transient performance. The speeds in the table are calculated scenarios and are not general allowable ranges for all circuits.

Frictional and local control relationship:

hf=fLDv22g+∑ Kv22g

In this regard, f is the Darcy friction coefficient and K is the local drop coefficient of the connection or equipment.

2–4. Cable selection and voltage drop control

Cable selection depends on consumer current, conductor material, insulation, installation method, ambient temperature, cable proximity, path length, short circuit and protection. Guide for selecting the conductor cross-section from Schneider Electric [441]

stage

Required data or review

Load determination

Voltage, rated current, starting current and consumer type

Determine installation conditions

Inside the pipe, tray, floor, wet environment or other conditions

Flow capacity

Apply the relevant correction coefficients

protection

Coordination of cable and protection device

Voltage Drop

Control in normal operation and start-up

short circuit

Thermal tolerance and cutting conditions

Environmental conditions

Moisture, chemicals, sunlight and mechanical damage

Final connection

Terminal fit, gland, connection and manufacturer's instructions

For a two-wire DC circuit with parallel conductors:

Δ V=2ρ LIS

In this regard:

• L: one-way length of the route, meters;

• I : current, ampere;

• S: cross-sectional area of each conductor, square millimeters;

• ρ: specific resistance of the conductor at the calculated temperature, ohm square millimeter/meter.

Educational example of voltage drop: 24 V DC circuit, constant current of 5 amps, one-way length of 20 meters and hypothetical special resistance of copper 0.0225.

Cross-sectional area, square millimeters

Voltage drop, volts

Percentage drop

1.5

3.00

12.50%

2.5

1.80

7.50%

4

1.125

4.69%

6

0.75

3.13%

10

0.45

1.88%

If the design limit of this example is 3%, the calculated cross section in terms of voltage drop is at least 6.25 mm2. Selecting a higher business class still requires other table controls.

This example does not authorize the use of 24 volts in any area of the fountain; Allowed voltage and type of protection must be determined separately.

2–5. Calculate the volume of the pond

All dimensions in the following relationships are in meters and volumes are in cubic meters.

Fig

Water volume relationship

Rectangle with fixed depth

V=LWh

Circle with constant depth

V=π D2h/4

Oval with constant depth

V=π abh/4, with a,b full diameters

A pond with different parts

V=∑ Ai hi

A rectangular pond with a length of 12 meters, a width of 5 meters and a water depth of 0.4 meters:

V=12×5×0.4=24 m3

It means 24 thousand liters of water.

In the executive estimate, the volume occupied by the structure and equipment should be subtracted from the geometric volume. The free space above the water, usable storage volume and the capacity to receive return water when stopping are separate concepts.

2–6. Estimation of evaporation and compensatory water

If the evaporation rate of the free surface is e in millimeters per day and the area is A in square meters:

Vevap,L/day=Ae

free surface area

Assuming 3 mm per day

Assuming 5 mm per day

Assuming 8 mm per day

25 square meters

75 liters

125 liters

200 liters

50 square meters

150 liters

250 liters

400 liters

100 square meters

300 liters

500 liters

800 liters

200 square meters

600 liters

1000 liters

1600 liters

The evaporation rate numbers in this table are hypothetical; The actual rate should be obtained from suitable climatic data or project measurements. This calculation does not cover additional evaporation from sprays and wet surfaces, droplet drift with wind, and filter washing losses.

For a period with approximately constant storage volume:

Vmakeup = Vevap +Vdrift +Vbackwash +Vdrain +Vleak -Veffective rainfall

Registering the compensatory water meter is the main tool for controlling this estimate during operation.

2–7. Estimation of pump power

For water:

Ph=0.002725QH

Pshaft=Phηp

Pelectrical= Phηpηmηd

In these relations, the power is in kilowatts, the flow is in cubic meters per hour, and the head is in meters. The efficiency of the pump, motor and drive are represented by ηp,ηm,ηd respectively. KSB pump power and performance reference [442]

The following table is calculated with a hypothetical total efficiency of 60%:

Flow rate, cubic meters per hour

Input power at 10 meters head

Input power at the head of 20 meters

10

0.45 kW

0.91 kW

20

0.91 kW

1.82 kW

40

1.82 kW

3.63 kW

60

2.73 kW

5.45 kW

For example, for a flow rate of 36, head of 15, and pump efficiencies of 0.65, motor 0.9, and drive 0.97, the input power is approximately 2.59 kW.

The nominal power of the motor must be controlled by the pump power curve within the permissible working range; Rounding the same number is not the only way to choose an engine.

Notes and references

  1. Source 93: Head Definition in KSB Technical Reference; www.ksb.com. Full address in the bibliography.

  2. Source 298: Conductor Cross Section Selection Guide from Schneider Electric; www.electrical-installation.org. Full address in the bibliography.

  3. Source 112: KSB Pump Power and Performance Reference; www.ksb.com. Full address in the bibliography.

About this edition

The supplied book has been transferred into website pages, including tables, equations and footnotes. The initial translation was machine generated, with terminology corrections and sample checks; a complete human technical review has not yet been performed. The diagrams have been recreated for the web with labels in the selected language.